Portable Fire Pump with Fixation

Main Advantage: Fixation of Xbd Type Centrifugal Fire Pump Set
Type: Self-Starting Diesel Generator
Installation Method: Portable
Stroke: Four Stroke
Cooling Method: Water Cooling
Output Type: AC Single Phase
Samples:
US$ 600/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
XBD
Transport Package
Wood Box
Specification
CE
Trademark
Liansheng or OEM
Origin
Shanghai, China
HS Code
84101330
Production Capacity
20000

Product Description


Portable Fire Pump with Fixation
Product name: Portable fire pump

Conditions of use:

XBD is applicable to transport temperature does not exceed 50 Centigrade water and is similar to the liquid water, water supply for fire water supply and other aspects.

The scope of performance parameter

XBD series a total of 170 specifications and its performance parameters range:

1. The rated flow from Q=5 to 80L/S

2. Pressure rating Mpa=0.35~2.8Mpa

3. Speed n=1480~2950r/min

4. Power P=3 ~ 315KW

5. Diameter of inlet Dna=50 ~ 200mm

6. Outlet diameter Dna=50 ~ 200mm
fault phenomenon failure cause elimination methods
  1.No power supply or one or two phase power supply is needed
Check all phases of power supply and restore power supply

 
  2.Poor contact of ac contactor and burning of coil
Repair or replace contactors

 
can not start 3.
The power switch is not closed, malfunction or damaged

 
Close the switch and replace it if the power indicator does not turn on
  4.
Thermal relay trip or damage

 
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started
  Water level is too low
Put water in the sink

 
  The motor burned
Repair or replace the motor

 
  1.Line is loose
Check wiring and tighten connectors

 
  2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
The manual is normal 3The frequency converter is damaged Repair or replace
Automatic transmission failure 4.Pressure switch damage Repair or replace
  5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage

The pump consumes too much power

 

Too much flow, impeller wear

 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow