• Useful Boiler Feed Water Supplying Pumps
  • Useful Boiler Feed Water Supplying Pumps

Useful Boiler Feed Water Supplying Pumps

Max.Head: 325m
Max.Capacity: 55m3/H
Driving Type: Motor
Impeller Number: Multistage Pump
Working Pressure: High Pressure Pump
Influent Type of Impeller: Double-Suction Pump
Samples:
US$ 100/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LDG
Position of Pump Shaft
Horizontal Pump
Pump Casing Combined
Horizontal Split Pumps
Mounting Height
Suction Centrifugal
Impeller
Closed
Usage
Pump, Pumps, Condensate Pump, Slurry Pump, Circulating Pump
Color
Blue
Transport Package
Mechanical Seal Packaging
Trademark
Lyson
Origin
China
Production Capacity
5000pieces/Month

Product Description

                                                                           Product introduction
Boiler feed water pump, DG type horizontal single-suction multi-stage centrifugal pump for the transport of water and physical and chemical properties similar to the water used in water. The type of pump DG25-80, DG45-80, DG85-80, DG150-100 four models;

Boiler feed pump flow of 25-150m3 / h, head up to 480-1100 meters. Can be transported below 280 ºC high temperature water, suitable for boiler feed water, factories and urban water use. It is suitable for conveying clean water with temperature below 110 ° C or other non-corrosive liquids with physicochemical properties similar to water. It is widely used in boiler feed water and urban water supply in industrial and mining enterprises. DG series pump is especially suitable for boiler feed water, but also widely used in pressure vessel water supply, hot water circulation, high building water supply, farmland irrigation, fire pressurization, hydraulic washing, food, brewing, medicine, chemical industry, aquaculture, environmental protection Other industries.

                                                                              Structural features

DG type is horizontal, single suction, multi-stage centrifugal pumps. Pump import and export are vertical upward. Tighten the pump suction section of the pump, the middle, the discharge section of the link into one.

Pump rotor mounted on the shaft impeller, balance plate and other components. The entire rotor is supported by plain bearings at both ends of the shaft. Bearings lubricated with circulating cooling water. The axial force of the rotor is balanced by the balance disc.

Shaft seal packing or mechanical seal. Seal at both ends of the shaft, built-in soft packing or mechanical seal. There is a certain amount of pressure gas water seal letter from the water seal, cooling effect. The shaft seal is equipped with a replaceable sleeve to protect the pump shaft. The pump is driven directly by the motor via a flexible coupling. From the motor end, the pump rotates clockwise.

Useful Boiler Feed Water Supplying Pumps
Useful Boiler Feed Water Supplying Pumps
                                                                           Parts and materials
Part Name Material Part Name Meterial
Inhalation section, the middle section High-quality carbon steel Seal ring stainless steel
Exhaust section, guide page High-quality carbon steel Guide vane sets stainless steel
Impeller, sleeve High-quality carbon steel Balance ring stainless steel
Impeller gear sleeve stainless steel Balance plate stainless steel
axis stainless steel Balance sleeve stainless steel
                                                                      Parameter
Q=8.5~55m³/h H=70~325m
n=2950r/min P=7.5~75kw
Dna=40~80mm DNm=32~65mm
                                                                       User's Guide

First, the operating rules must see
Warning: Operation procedures, habits, etc., if violated, may cause personal injury

Caution: Operation procedures, habits, etc., if violated, may cause damage to the equipment

Note: Operating procedures, conditions, etc. should be given high priority.

Second, the pump assembly and disassembly
1, the pump assembly DG pump assembly quality directly affects the quality of the pump can be normal operation, and affect the pump life and performance parameters; affect the unit vibration and noise, the assembly should pay attention to the following points:

a. The concentricity of the fixed parts after the combination of parts is ensured by the manufacturing precision and assembly quality of the parts. The processing precision and surface roughness of the parts should be guaranteed. The touching and scratching of the parts should not be allowed. Molybdenum disulfide used as a sealant should be clean. Tightening screws, bolts should be force evenly.

b, impeller outlet flow path and guide vane inlet flow channel is dependent on the axial size of the parts to ensure that. The quality of the flow channel has a direct impact on the performance of the pump, so the size of the pump can not be adjusted.

c, After the pump is assembled, before turning on the filler, turn the pump rotor by hand to check whether the pump rotor rotates freely in the housing and whether the axial movement meets the specified requirements.

d, the above inspection meets the requirements, add packing at the shaft seal at both ends of the pump, pay attention to the relative position of the packing rings in the packing room.

2, the pump removal

a, demolition to be carried out in the reverse order with the assembly, demolition should be strictly protected parts manufacturing accuracy from damage.

b, remove the wear bar should be the first cushion with the middle pad, so as not to loosen the middle of the stop after the shaft bending.

Third, the installation of the pump
In addition to the installation of this pump to meet the general installation of technical requirements, but also should note the following:

1, When the combination of motor and pump is installed, the axial end of the pump coupling should be pulled out axially, and the 3-5mm end clearance value should be retained to ensure the axial clearance between the two couplings of the pump and the motor.

Note: Make sure the floor leveling, equipment level after a good degree of grouting

CAUTION: For the installation to be successful, the coupling adjustment must be correct and the flexible coupling can not compensate for any significant misalignment. Misalignment can cause rapid wear, noise, vibration, and damage to the equipment. Therefore, the coupling must be adjusted within the limits given.

Caution: Measures must be taken to support the pump inlet and outlet pipes to prevent excessive pump load

2, pump and motor shaft center line should be in the same horizontal line.

3, the pump can only withstand its own internal forces, can not afford any external force.

Fourth, the pump start, run, stop
(A) start:

WARNING: For the operator's safety, do not exceed the pump nameplate in order to avoid endangering the safety of the equipment and the operator. To ensure the smooth operation and maintenance of pumps and other movements, please refer to the instructions.

1, the pump should be operated before the first rotor, check the rotor is flexible.

2, check the motor steering is consistent with the pump steering.

3, close the pump outlet gate valve, pressure gauge cock, with the delivery of liquid or vacuum system to exclude the suction tube and the body of the air pump (no empty car start running).

4, check the pump and motor coupling bolt tightness and safety around the pump, so that the pump is ready to start.

WARNING: EQUIPMENT OPERATES ONLY FOLLOWING THE COUPLING SHIELD AND MISCELLANCE OF THE SAME CAUSED BY PERSONAL INJURY.

5, start the pump, to be normal operation of the pump, open the pressure gauge cock, slowly open the outlet gate valve, press the outlet pressure gauge to control the pump given head.

(B) run:

1, This type of pump balances the axial force by the internal balance mechanism, the balance device has a balanced liquid outflow, and the balance liquid is connected to the suction section by the balance water pipe.

2, this type of pump bearing all have cooling devices, pumps must be connected before the cooling water pipe. Bearing temperature changes reflect the assembly quality of the pump, the bearing temperature shall not exceed 35 ºC ambient temperature, the maximum temperature should not exceed 75 ºC.

WARNING: Handling equipment that is not properly lubricated may cause bearing heat, breakage, pump stalls, equipment damage, and personal injury to the operator.

3, the pump rotor in operation there is a certain degree of axial swimming, the motor and the pump should ensure that the gap between the two coupling end face value.

4, the pump should be checked during operation impeller, seal ring, guide vane sets, balance disc, sleeve wear, excessive wear should be promptly replaced.

WARNING: DO NOT ATTEMPT TO REPAIR, MAINTENANCE OR CLEAN UP IN THE ROTARY MACHINE AS NEITHER OF AN EMERGENCY OPERATOR.

5, the user should be based on the specific circumstances set out a more detailed operating procedures.

(C) Parking: stop the pressure gauge cock before closing, and then slowly close the exit gate valve until the exit gate valve is closed to stop the motor.

Fifth, the pump may occur failure and solution
Symptoms
 
Possible Causes
 
Solution
 the pump is not absorbent; pressure gauge and vacuum gauge pointer violently beating Injected into the water pump is not enough; pump or instrument leaks Fill the water pump again; tighten or plug the leak out
the pump does not absorb water, the vacuum gauge shows a high degree of vacuum Water inlet pipe is not open or blocked; water absorption resistance is too large; water absorption height is too large to exceed allowable value Check the inlet pipe; clean or replace the suction pipe; reduce the water absorption heigh
look at the pressure gauge water pump pressure, and the pump is still water Outlet resistance is too large; rotation direction is not correct; impeller blockage; pump speed is not enough Check or shorten the outlet pipe; change the motor steering; clean the impeller; increase the pump shaft speed
 traffic is lower than expected Pump blocked; too much wear on the seal ring; insufficient speed Clean the pump and pipe; replace the seal ring; increase the pump shaft speed
 the pump consumes too much power Gland packing too tight; impeller wear; pump water supply increased Loosen the packing gland or remove the packing; replace the impeller; adjust the gate valve to reduce the flow rate
 the pump in the process of abnormal sound, flow down until no water; balance device early wear and tear Gate valve open too much; suction pipe resistance is too large; there is air infiltration at the water absorption; excessive water absorption; the liquid temperature is too high Adjust gate valve to reduce flow; check suction pipe; check bottom valve; reduce suction height; tighten or plug leaks; reduce liquid temperature
pump vibration Pump shaft and motor axis are not in the same center line Align pump with motor shaft centerline
bearing overheating No oil or oil dirty; pump shaft and motor shaft is not a centerline Fill or change oil; align the shaft centerline

 

Send your message to this supplier

*From:
*To:
avatar Miss Jessica Zhang
*Message:

Enter between 20 to 4,000 characters.