• Sanitary Centrifugal Pump with Double Suction
  • Sanitary Centrifugal Pump with Double Suction
  • Sanitary Centrifugal Pump with Double Suction
  • Sanitary Centrifugal Pump with Double Suction
  • Sanitary Centrifugal Pump with Double Suction

Sanitary Centrifugal Pump with Double Suction

Max.Head: >150m
Max.Capacity: >400 L/min
Driving Type: Motor
Impeller Number: Multistage Pump
Working Pressure: High Pressure Pump
Influent Type of Impeller: Double-Suction Pump
Samples:
US$ 600/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LS
Position of Pump Shaft
Horizontal Pump
Pump Casing Combined
Horizontal Split Pumps
Mounting Height
Suction Centrifugal
Impeller
Closed
Usage
Pump
Main Features
Double Suction
Transport Package
Wood Box
Specification
CE
Trademark
Liansheng or OEM
Origin
Shanghai, China
HS Code
84101330
Production Capacity
50000/Month

Product Description


Sanitary Centrifugal Pump with Double Suction
Products Name:Sanitary centrifugal pump with Double Suction

Conditions of use:
LS is applicable to transport water and physical and chemical properties of temperature does not exceed 80 celsius is similar to that of liquid water.

Performance parameters

The series has a total of 29 varieties, 64 specifications and its performance parameters range:

1. Q=133 ~ 3170m3/h

2. Flow lift H=10 ~ 125m

3. Speed n=970, 1450, 2950r/min

4. Power P=18.5 ~ 850kW

5. Diameter of inlet Dna=150 ~ 600mm

6. Outlet diameter DNm=100 ~ 500mm
fault phenomenon failure cause elimination methods
  1.No power supply or one or two phase power supply is needed
Check all phases of power supply and restore power supply

 
  2.Poor contact of ac contactor and burning of coil
Repair or replace contactors

 
can not start 3.
The power switch is not closed, malfunction or damaged

 
Close the switch and replace it if the power indicator does not turn on
  4.
Thermal relay trip or damage

 
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started
  Water level is too low
Put water in the sink

 
  The motor burned
Repair or replace the motor

 
  1.Line is loose
Check wiring and tighten connectors

 
  2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
The manual is normal 3The frequency converter is damaged Repair or replace
Automatic transmission failure 4.Pressure switch damage Repair or replace
  5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage

The pump consumes too much power

 

Too much flow, impeller wear

 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow
Sanitary Centrifugal Pump with Double Suction
Sanitary Centrifugal Pump with Double Suction

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
65
Year of Establishment
1998-09-10