• Single-Stage Single-Suction Horizontal Centrifugal Water Pump
  • Single-Stage Single-Suction Horizontal Centrifugal Water Pump
  • Single-Stage Single-Suction Horizontal Centrifugal Water Pump
  • Single-Stage Single-Suction Horizontal Centrifugal Water Pump

Single-Stage Single-Suction Horizontal Centrifugal Water Pump

Max.Head: 110m-150m
Max.Capacity: >400 L/min
Driving Type: Motor
Impeller Number: Single-Stage Pump
Working Pressure: High Pressure Pump
Influent Type of Impeller: Single Suction Pump
Samples:
US$ 137/Set 1 Set(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
IS
Position of Pump Shaft
Horizontal Pump
Impeller
Closed
Usage
Pump, Pumps, Condensate Pump, Slurry Pump, Circulating Pump, Water Transport
Type
Is
Color
Green
Material
Cast Iron
Motor
100% Cooper Wire
Pressure
High Pressure
Transport Package
Wooden Box
Specification
ISO9001/CE
Trademark
LYSON or OEM
Origin
Shanghai, China
HS Code
8413709990
Production Capacity
50000/Month

Product Description


Single-Stage Single-Suction Horizontal Centrifugal Water Pump

Products Name: Single-stage Single-suction Horizontal Centrifugal Water Pump

Conditions of use: Suitable for conveying the temperature under 80 celsius water and similar to that of liquid water, pump system working pressure of up to 12.5 bar.

The scope of performance parameter: This series a total of 29 species, 151 kinds of specifications and its

performance parameters range:

1 flow Q=5.5 ~ 315m3/h

2. Lift H=3.7 ~ 125m

3. Speed n=1450/2950 r/min

4. Power P=0.25~ 110kW

5. Diameter of inlet Dna=50 ~ 200mm

6. Outlet diameter DNm=32 ~ 150mm
fault phenomenon failure cause elimination methods
The manual is normal
Automatic transmission failure
1.No power supply or one or two phase power supply is needed
Check all phases of power supply and restore power supply

 
Water level is too low
Put water in the sink

 
The motor burned
Repair or replace the motor

 
1.Line is loose
Check wiring and tighten connectors

 
2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
3The frequency converter is damaged Repair or replace
4.Pressure switch damage Repair or replace
5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage

The pump consumes too much power

 

Too much flow, impeller wear

 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow
Single-Stage Single-Suction Horizontal Centrifugal Water Pump
Single-Stage Single-Suction Horizontal Centrifugal Water Pump