Fire Pumping Station with Centrifugal Fire Pumps

After-sales Service: 1 Year
Warranty: 1 Year
Max.Head: >150m
Max.Capacity: >400 L/min
Driving Type: Electric
Material: Cast Iron
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
HHL
Structure
Multistage Pump
Assembly
Liquid Pumps
Power
Electric
Start Up
Electric Pump
Type
Blade Pump
Application
Slurry Pump
Industry
Fire Pump
Media
Water
Performance
Explosion-Proof Pumps
Theory
Centrifugal Pump
Main Advantage
Xq-Type Fixed Centrifugal Fire Pumps
Place of Origin
Shanghai, China
Brand Name
Lyson
Standard or Nonstandard
Standard
Transport Package
Standard Export Packing or According to Customers′
Specification
CE
Trademark
LYSON or OEM
Origin
Shanghai, China
HS Code
84101330
Production Capacity
20000

Product Description


Fire Pumping Station with Centrifugal Fire Pumps
Product Description

Products Name:fire pumping station with Fixed Centrifugal Fire Pumps


Conditions of Use:
1, Equipment should be installed indoors, for the basic level of coagulation platform or equipment can guarantee the normal work of the formation of the ground.
2, Since irrigation water inflow should be able to pump inlet cavity and the pressure of equipment is not more than 0.5Mpa, the water quality should comply with the Fire Code requirements.
3, Ambient temperature 0 ~ 50 Celsius does not freeze, humidity <90% non-condensing, non-corrosive gases, non-inflammable and explosive gas.
4, Permit altitude 1000m.

Product Features:

1, XBD Series fire pressure water supply equipment, in the control system uses programmable control technology, fire main pump soft start timing technology, effectively ensure the safe operation of fire fighting equipment.
2, Effective control of the tank the ratio of gas and water to ensure that by Fire Code (30 seconds) or (10 seconds) design an effective water volume.
3, May have dual power supply design, and automatically switch.
4, Programming multi-function control, fire main pump timing soft-start inspection. Fire Control Center with computer networking.
5, Acceptable to a wide range of fire signals, can be networked with the Fire Services Center.
 
fault phenomenon failure cause elimination methods
  1.No power supply or one or two phase power supply is needed  
Check all phases of power supply and restore power supply
 
 
  2.Poor contact of ac contactor and burning of coil  
Repair or replace contactors
 
 
can not start 3.
The power switch is not closed, malfunction or damaged
 
 
Close the switch and replace it if the power indicator does not turn on
  4.
Thermal relay trip or damage
 
 
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started
  Water level is too low  
Put water in the sink
 
 
  The motor burned  
Repair or replace the motor
 
 
  1.Line is loose  
Check wiring and tighten connectors
 
 
  2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
The manual is normal 3The frequency converter is damaged Repair or replace
Automatic transmission failure 4.Pressure switch damage Repair or replace
  5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage
 
The pump consumes too much power
 
 
 
Too much flow, impeller wear
 
 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow
Fire Pumping Station with Centrifugal Fire Pumps
Fire Pumping Station with Centrifugal Fire Pumps
Fire Pumping Station with Centrifugal Fire Pumps
Fire Pumping Station with Centrifugal Fire Pumps
Fire Pumping Station with Centrifugal Fire Pumps
Fire Pumping Station with Centrifugal Fire Pumps

♦ ESTABLISHED IN THE SIXTIES


♦ ONE OF THE FIRST THROUGH THE ISO9001:2008 DOMESTIC,

INTERNATIONAL QUALITY SYSTEM CERTIFICATION


♦ SILVER MEDAL WAS AWARDED AT THE NATIONAL CONFERENCE ON THE

APPLICATION OF SPARK CUP TECHNOLOGY


♦ WIN THE NATIONAL AWARD FOR EXCELLENCE IN CIVILIZATION COMPETITION 


♦ GET THE LC OF THE CHINESE GOVERNMENT

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
65
Year of Establishment
1998-09-10