Td Series High Temperaturer Pipeline Pump

Product Details
Customization: Available
Max.Head: 50-80m
Max.Capacity: <50 L/min

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
65
Year of Establishment
1998-09-10
  • Td Series High Temperaturer Pipeline Pump
  • Td Series High Temperaturer Pipeline Pump
Find Similar Products

Basic Info.

Model NO.
LTD 32-200
Driving Type
Motor
Material
Cast Iron
Structure
Single-stage Pump
Assembly
Pipeline Pump
Power
Electric
Start Up
Electric Pump
Type
Blade Pump
Application
Clarified Water Pump, Oil Transfer Pump, Chemical Pump, Booster Pump
Industry
Air Conditioning Pump
Media
Water
Performance
No Leakage Pump
Theory
Centrifugal Pump
International Standard
ISO2858
Transport Package
Wood Box
Specification
CE
Trademark
Liansheng or OEM
Origin
Shanghai, China

Product Description

Td Series High Temperaturer Pipeline Pump
LTD In-line Circulation Pump  
LTD In-line Circulation Pump    
Introduction 
The type TD pumps are single stado in-linecentrifugal pumps,equpped with standard motor and mechical seal.Comparing with other pumps in similar structure,these pumps are less accessible to the impurity in the liquid. 
NPSH 
To avold the cavitations,and lessen the libration and noise,you are suggested to adopt NPSH in table 2,to make sure that the pumps are under optimal operation conition. The data in the sheet are relative pressure(Bar),which can be read on manometer at the inlet side of the pumps. 
Application 
The pumps are applicable for clean,attenuate,non-corrosive,non-flammable,and non-explosive liquid which shall not contain any solid grain and fibre that might damage the pump me chanically or chemically.
Liquid temperature : -15°C~120°C 
Max.Pressure: PN16
Product Power: 1.1-45kw
fault phenomenon failure cause elimination methods
  1.No power supply or one or two phase power supply is needed  
Check all phases of power supply and restore power supply
 
 
  2.Poor contact of ac contactor and burning of coil  
Repair or replace contactors
 
 
can not start 3.
The power switch is not closed, malfunction or damaged
 
 
Close the switch and replace it if the power indicator does not turn on
  4.
Thermal relay trip or damage
 
 
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started
  Water level is too low  
Put water in the sink
 
 
  The motor burned  
Repair or replace the motor
 
 
  1.Line is loose  
Check wiring and tighten connectors
 
 
  2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
The manual is normal 3The frequency converter is damaged Repair or replace
Automatic transmission failure 4.Pressure switch damage Repair or replace
  5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage
 
The pump consumes too much power
 
 
 
Too much flow, impeller wear
 
 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow