Additive Pipe Pressure (negative pressure) Water Supply Equipment

Product Details
Customization: Available
Max.Head: 50-80m
Max.Capacity: 200-300 L/min
Still deciding? Get samples of US$ 600/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
65
Year of Establishment
1998-09-10
  • Additive Pipe Pressure (negative pressure) Water Supply Equipment
  • Additive Pipe Pressure (negative pressure) Water Supply Equipment
  • Additive Pipe Pressure (negative pressure) Water Supply Equipment
Find Similar Products

Basic Info.

Model NO.
LZW(I)
Pressure Medium
Water
Type
Desktop
Position of Pump Shaft
Vertical Edge
Certification
CE, ISO, RoHS
Series
Lzw(I)
Transport Package
Wood Box
Specification
CE
Trademark
Liansheng or OEM
Origin
Shanghai, China
HS Code
84101330
Production Capacity
2000

Product Description


Additive Pipe Pressure (negative pressure) Water Supply Equipment
Products Name: Additive Pipe Pressure (negative pressure) Water Supply Equipment

Working conditions:

1, environment temperature: 4 Centigrade ~40 Centigrade;

2, relative humidity: <90% (20 Centigrade), outdoor allow 95%, without dew;

3: <0.5g, vibration, vibration frequency 10Hz~150Hz, the maximum acceleration should not exceed 5m/s2;

4, tilt<5 °

5, the power supply frequency: 50 Hz ± 5%;

6, the power supply voltage: 380V ± 10%;

7, altitude: Not more than 1000m;

8, equipment operation site should be no conductive or explosive dust, non corrosive metal or gas insulation failure or steam.

9, pressure precision: <0.01Mpa

10. Pressure range: 0~2.0Mpa

11, flow range: 0~600m3/h
fault phenomenon failure cause elimination methods
  1.No power supply or one or two phase power supply is needed
Check all phases of power supply and restore power supply

 
  2.Poor contact of ac contactor and burning of coil
Repair or replace contactors

 
can not start 3.
The power switch is not closed, malfunction or damaged

 
Close the switch and replace it if the power indicator does not turn on
  4.
Thermal relay trip or damage

 
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started
  Water level is too low
Put water in the sink

 
  The motor burned
Repair or replace the motor

 
  1.Line is loose
Check wiring and tighten connectors

 
  2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
The manual is normal 3The frequency converter is damaged Repair or replace
Automatic transmission failure 4.Pressure switch damage Repair or replace
  5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage

The pump consumes too much power

 

Too much flow, impeller wear

 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow
Additive Pipe Pressure (negative pressure) Water Supply Equipment
Additive Pipe Pressure (negative pressure) Water Supply Equipment