Fire Automatic Constant Pressure Water Supply Equipment Industry Pump

Max.Head: >150m
Max.Capacity: >400 L/min
Driving Type: Motor
Impeller Number: Multistage Pump
Working Pressure: High Pressure Pump
Influent Type of Impeller: Single Suction Pump
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HXQ
Position of Pump Shaft
Vertical Pump
Pump Casing Combined
Verticaljoint Surface Pump
Mounting Height
Suction Centrifugal
Impeller
Closed
Usage
Pump, Pumps, Condensate Pump, Slurry Pump, Circulating Pump
Color
Red
Certificate
ISO9001:2000
Material
Cast Iron
Application
Water Supply Equipment
Standard or Nonstandard
Standard
Theory
Cast Iron
Transport Package
Wooden Sealed Packaging
Specification
caliber: 20~300mm
Trademark
Lyson
Origin
China
HS Code
8413709990
Production Capacity
5000pieces/Month

Product Description

                                                   Introduction
Fire pressure water supply equipment usually by the pressure tank, pump units, control cabinets and accessories. In the pump start and stop state can fire water pipe network equipment.
HXQ series of fire pressure water supply equipment for fire water supply system, the series is divided into fire special water supply equipment and fire and life (production) shared water supply equipment two series. As a complete set of fire fighting equipment to meet the automatic fire all the technical requirements.(HXQZ said fire-fighting dedicated,HXQG said fire and life production sharing, with fire main pump.)

Fire Automatic Constant Pressure Water Supply Equipment Industry Pump
Fire Automatic Constant Pressure Water Supply Equipment Industry Pump
Fire Automatic Constant Pressure Water Supply Equipment Industry Pump
Fire Automatic Constant Pressure Water Supply Equipment Industry Pump
Fire Automatic Constant Pressure Water Supply Equipment Industry Pump
                                                                Features
HXQ series of fire pressure water supply equipment, in the control system uses a programmable control technology, fire main pump timing soft-start technology, effectively ensure the safe operation of fire equipment. Its characteristics are as follows:
       1, can have dual power supply design, and can automatically switch;
       2, multi-function programming control, fire main pump timing soft start inspection;
       3, with the fire control center computer networking;
       4, can accept a variety of fire signals, with fire center networking.

                                                               structure

classification

1) according to the form of pressure tank work is divided into

(1) Gas-fired fire pressure water supply equipment (2) Capsule fire pressure water supply equipment (3) Nitrogen top pressure fire pressure water supply equipment

(2) According to whether the fire pump is divided into groups

a. An ordinary fire pressure water supply equipment with a fire pump group b. An emergency fire pressure water supply equipment without a fire pump group

                                                         Design selection points

1) The manufacturer of the pressure water tank shall hold the pressure vessel manufacturing license or registration, and shall have a sound quality management system and system.

2) Equipment outsourcing parts must have a product certification and admission test before use. Equipment, pressure tank, pump units, electrical components and other components, should be tested before the assembly and use. The use of on-site assembly of equipment, on-site inspection machine performance.

3) should hold the production license issued by the relevant departments.

4) When selecting this product, the following requirements should be put forward: equipment composition, equipment classification, equipment working pressure, equipment design flow, pressure tank specification quantity, equipment material and hygiene requirements.

5) The overall structure of the equipment, water pipelines, gas pipelines and electrical wiring layout should be reasonable, there should be left space for installation and maintenance to facilitate operation.

6) Equipment should be set on the pipeline safety valve, the cracking pressure is not greater than 1.1 times the maximum working pressure.

7) fire and life (production) shared equipment must have a separate fire outlet.

                                                     Point

conditions

construction, installation points

1), pressure tank fire hydraulics equipment, its volume, pressure, water level and working pressure should meet the design requirements.

2) The installation of safety valves, pressure gauges, drains, water level indicators, etc. on fire-fighting pneumatic water supply equipment shall comply with the requirements of the product instruction manual.

3) The installation position of fire pressure water supply equipment, the direction of inlet pipe and outlet pipe should meet the design requirements; the installation should be provided with access roads around its circumference, its width should not be less than 0.7m, the distance from the top of fire pressure water supply equipment to the floor or beam bottom Not less than 0.6m.

4), equipment to the scene to be devanned inventory. Installation in place to be leveling, grouting. Pipeline connection and electrical control wiring shall be controlled drawings, check correct.

5) After the equipment is installed, the equipment must be commissioned and commissioned. Including the start-stop control of the pump, each valve switch, and equipment cleaning, water test run.

                                                         Product Standards
"Fixed fire water supply performance requirements and test methods - Part 1: Fire pressure water supply equipment"

GA 30.1-2002

Pressure relief devices for fire fighting - Performance requirements and test methods

Performance Requirements and Test Methods for Flow Indicators of GA 32 Sprinkler Systems

GB 7251.1 Low-voltage switchgear and control equipment - Part 1: Type test and part-type test complete sets of equipment

GB 5135 automatic sprinkler system sprinkler head technical requirements and test methods

GB / T 3797 electronic control e 
quipment Part 2: Electronic devices equipped with electronic control equipment

GB / T 3222 Acoustic environment noise measurement methods

GB / T 3216 centrifugal pumps, mixed flow pumps, axial flow pumps and vortex pump test methods

GB / T 2682 electrical complete sets of lights and button color

GB / T 2681 electrical equipment in the wire color

GB / T 2423.2 Basic environmental testing for electric and electronic products Part 2: Test methods Test B: High temperature

GB / T 2423.1 Basic environmental testing for electric and electronic products Part 2: Test methods Test A: Low temperature

GB / T 2421 Environmental testing for electric and electronic products Part 1: General

GB 150 steel pressure vessel
fault phenomenon failure cause elimination methods
  1.No power supply or one or two phase power supply is needed  
Check all phases of power supply and restore power supply
 
 
  2.Poor contact of ac contactor and burning of coil  
Repair or replace contactors
 
 
can not start 3.
The power switch is not closed, malfunction or damaged
 
 
Close the switch and replace it if the power indicator does not turn on
  4.
Thermal relay trip or damage
 
 
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started
  Water level is too low  
Put water in the sink
 
 
  The motor burned  
Repair or replace the motor
 
 
  1.Line is loose  
Check wiring and tighten connectors
 
 
  2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
The manual is normal 3The frequency converter is damaged Repair or replace
Automatic transmission failure 4.Pressure switch damage Repair or replace
  5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage
 
The pump consumes too much power
 
 
 
Too much flow, impeller wear
 
 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
65
Year of Establishment
1998-09-10