Ldla Multistage Vertical Centrifugal Pumps

Product Details
Customization: Available
Max.Head: 230m
Max.Capacity: 216m³/H
Still deciding? Get samples of US$ 100/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
65
Year of Establishment
1998-09-10
  • Ldla Multistage Vertical Centrifugal Pumps
  • Ldla Multistage Vertical Centrifugal Pumps
  • Ldla Multistage Vertical Centrifugal Pumps
  • Ldla Multistage Vertical Centrifugal Pumps
Find Similar Products

Basic Info.

Model NO.
LDLA
Driving Type
Motor
Impeller Number
Multistage Pump
Working Pressure
High Pressure Pump
Influent Type of Impeller
Single Suction Pump
Position of Pump Shaft
Vertical Pump
Pump Casing Combined
Verticaljoint Surface Pump
Mounting Height
Suction Centrifugal
Impeller
Closed
Usage
Pump, Pumps, Condensate Pump, Slurry Pump, Circulating Pump
Colour
Costomize
Certificate
ISO9001:2000
Transport Package
Wooden Sealed Packaging
Specification
caliber: 20~350mm
Trademark
Lyson
Origin
China
Production Capacity
5000pieces/Month

Product Description

                                                                   Introduction
Multistage centrifugal pump is to have the same function of more than two centrifugal pumps together, the structure of the fluid channel, the performance of the first level of the media pressure relief port and the second level of the import communication, the second level of media leakage Pressure port is connected with the third level of imports, so the series of institutions formed a multi-stage centrifugal pump.Adopted the national recommended energy-efficient hydraulic model, with high efficiency and energy saving, wide range of performance, safe and stable operation, low noise, long life, easy installation and maintenance; By changing the pump material, sealed form and increase the cooling system can be transported Hot water, oil, corrosive and abrasive media.
LDLA, LDWA series consists of vertical two horizontal series for conveying temperature ≤ 80 ºC water and physical and chemical properties similar to clear liquid.Adapt to mine and urban water supply and drainage projects.

Ldla Multistage Vertical Centrifugal Pumps
Ldla Multistage Vertical Centrifugal Pumps
Ldla Multistage Vertical Centrifugal Pumps
Ldla Multistage Vertical Centrifugal Pumps
                                                   Application
LDLA/LDWA series is suitable for conveying clean water with temperature not more than 80 ºC and liquid with physical and chemical properties similar to clear water.Municipal water supply and booster, industrial and mining enterprises water supply, domestic water supply, air conditioning, cooling system cooling water supply system, fire sprinkler system water supply, boiler water supply and condensing systems
                               
Structure Description
1, LDLA Vertical Multistage Centrifugal Pump and LDWA Horizontal Multistage Centrifugal Pump are vertical and horizontal dual-purpose pumps which are common to most parts, and the relative positions of inlet and outlet can be composed according to the requirements of users' installation and installation drawings Various directions.
2, the two types of pumps are rigid coupling, impeller shaft and motor shaft directly. The pump uses adjustable wear-resistant packing seal or user requirements with mechanical seal sealed two forms, to remove and replace the mechanical seal, just remove the motor and coupling, you can easily replace and check.
3, to meet the hydraulic performance and anti-cavitation performance requirements, the series of products through computer-aided design, the first impeller and the secondary impeller, guide vane to better meet the requirements of high efficiency, good anti-cavitation performance, but also to energy Each impeller is evenly distributed. The material of the impeller is two kinds of high-strength cast iron and wear-resistant cast bronze. The impeller can balance its own axial force.
4, into the water section, the middle section, the water section are high-strength cast iron, with the O-ring seal at the face seal, and by tightening the bolt tension to achieve the sealing effect.
                                 
  Features

1, multi-stage centrifugal pump for the vertical structure, with a small footprint, pump center of gravity coincident with the center of the pump, which runs smoothly, small vibration, long life.

2, multi-level centrifugal pump diameter and the same horizontal centerline, without changing the pipeline structure, can be directly installed in any part of the pipeline, the installation is extremely convenient.

3, the motor plus rain cover can be placed directly in the outdoor use, without the need to build pump room, greatly saving capital investment.

4, multi-stage centrifugal pump head can be changed by pump series (number of impeller) to meet different requirements, it is applicable to a wide range.
Multi-stage centrifugal pump structure
Multi-stage centrifugal pump structure
5, the shaft seal with carbide mechanical seal, reliable seal, no leakage, mechanical loss.

6, energy efficient, beautiful appearance.

7, Note 50 caliber inner casting above forming.

                                                      Implementation standards

Collapse national standards:

"Centrifugal pump technical conditions ()" GB / T16907-1997

"Centrifugal pump technical conditions ( class)" GB / T5656-1994

"Centrifugal pump technical conditions (Class )" GB / T5657-1995

"Determination of pump flow method" GB / T3214-91

"Centrifugal pump efficiency" GB / T13007-1991

"Centrifugal pumps, axial flow pump conditions" GB / T13009-91

"Centrifugal pump, mixed flow pump, axial flow pump and scroll pump test method" GB3216-89

"Centrifugal pump, mixed flow pump and axial flow pump hydraulic performance test specification precision class" GB / T18149-2000

"Centrifugal pumps, mixed flow pumps and axial flow pump NPSH" GB / T13006-1991

Collapse industry standards:

"Small multistage centrifugal pump type and basic parameters" JB / T6435.1-92

"Small multistage centrifugal pump technical conditions" JB / T6435.1-92

 Engineering standards:

"Building Water Supply and Drainage and Construction Quality Acceptance Code" GB50242-2002

"Building Water Supply and Drainage Design Code" GB50015-2003


                                                    Attributes
Discharge diameter: 40-80 (mm) Lift: 5-250 (m)
Inlet diameter: 50-100 (mm) Impeller Structure: Closed Impeller
Structure Principle: Jet Pump  Impeller Number: 1
Shaft position: Side vertical Material: cast iron
Impeller Inhalation: Single suction Model: LVP (LHP) Series Multistage Centrifugal Pump
Flow: 3.6-150 (m3 / h) NPSH: 2.5-7 (m)
Uses: Pipeline pump shaft power: 0.37-90 (kW)
Performance: Frequency Attributes: Industrial
                                             Performance parameters
Q=4.9~216m³/h H=18~230m
n=1480/2950 r/min P=0.37~90kw
Dna=50~100mm DNm=40~80mm
Pump inlet maximum working pressure≤1.0Mpa Pump maximum working pressure≤3.0Mpa
                                    Maintenance

Cleaning items

First, scrape the inner and outer surface of the impeller and seals and bearings and other places accumulated scale and rust and other objects, and then water or compressed air cleaning, blowing clean.

Second, clean the housing surface of the joint accumulation of grease and rust.

Third, clean the water seal tube and check the tube is smooth.

Fourth, clean bearings and bearings, remove grease, and then wash the oil ring and oil surface meter. Ball bearing application of gasoline cleaning.

Fifth, temporary zero assembly, parts, after cleaning should be oiled protection.

Fundamentals of folding and cleaning

1, to ensure that meet the requirements of the degree of cleanliness of parts, in the repair, a variety of mechanical parts, the degree of cleanliness requirements are not the same. In the assembly, the cleaning requirements of the mating parts are higher than those of the non-matching parts, the moving parts are higher than the static parts, and the precision parts are higher than the non-precision parts. For spray, plating, bonding the surface of the workpiece, the cleaning requirements are high. Cleaning must be based on different requirements, take a different cleaning agent and cleaning

Method to ensure the required cleaning quality.

2, to prevent corrosion of parts, precision parts do not allow any degree of corrosion. When the parts to be parked for some time after cleaning, should consider the antirust ability of cleaning fluid or consider other anti-rust measures.

3, to ensure safe operation, to prevent fire or poison the human body and cause environmental pollution.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier