High Head Sewage Pump of Liquid

Product Details
Customization: Available
Method: Combined Treatment
Usage: Industrial, Home, Agriculture, Hospital

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
65
Year of Establishment
1998-09-10
  • High Head Sewage Pump of Liquid
  • High Head Sewage Pump of Liquid
  • High Head Sewage Pump of Liquid
  • High Head Sewage Pump of Liquid
  • High Head Sewage Pump of Liquid
Find Similar Products

Basic Info.

Model NO.
YW
Transport Package
Wood Box
Specification
CE
Trademark
liansheng or OEM
Origin
Shanghai, China
HS Code
84101330
Production Capacity
50000/30days

Product Description


High Head Sewage Pump of Liquid
Products Name:high head sewage pump of Liquid

A, product introduction:

YW type liquid type non clogging sewage pump is Lian Sheng on the basis of the introduction of foreign advanced technology, combined with the use of domestic water pump features a new generation of pump products designed and produced successfully, with significant energy saving effect, anti winding, no blocking, automatic installation and automatic control characteristics, in the carriage of solid particles and long fiber waste, has a unique effect.

Liquid sewage pump hydraulic performance of advanced, mature, product performance testing, the indicators are in line with the requirements of the relevant design.

Lian Sheng products using computer design and optimization, the company has strong technical force, rich production experience and perfect testing means, so as to ensure stable and reliable product quality.

Two, applicable scope:

YW type liquid type non clogging sewage pump is suitable for chemical, petroleum, pharmaceutical, mining, paper, power plant and the city sewage treatment, municipal engineering, public facilities, sewage and other conveying sewage with particles.

Three, product features:

1. Anti-jamming design of hydraulic components, big channel, greatly improving the through capacity of sewage, solid particles can effectively for 50% of pump diameter by 5 times of pump diameter and the diameter of fiber material.
2, reasonable design, reasonable matching motor, high efficiency, energy-saving effect is remarkable.
3. Dual path series seal, mechanical seal made of tungsten carbide hard wear-resistant, durable, wear-resistant, can pump the security more than 8000 hours of continuous operation.
4, the pump has the advantages of compact structure, small volume, convenient to move, simple installation.
5, automatic control cabinet is equipped with liquid level, according to the change of liquid level required, automatically control the pump to start and stop, without special care, is extremely easy to use.
6, liquid type non clogging sewage pump is a vertical structure, when the pump body immersed in a fluid is easy to start, there is no exhaust time, at the same time with no leakage and other characteristics, under fluid depth is 15 meters.
7, shaft connecting structure is advanced and reliable, pump and motor shaft coupling, pump shaft size precision, ensure the smooth operation of the pump, with sufficient safety factor.
8, sewage pump pipe installation and pipe installation two, supporting a disk and a square plate mounting, suitable for different needs.
Four, the technical parameters:
1. Traffic: 8-2600m3/h;
2. Head: 7-60m;
3. Speed: 740-2900r/min;
4. Aperture: φ 25- φ 500;
5. The temperature range of -15-+60 celsius;
6. Working pressure: ≤ 1.0Mpa.
fault phenomenon failure cause elimination methods
  1.No power supply or one or two phase power supply is needed  
Check all phases of power supply and restore power supply
 
 
  2.Poor contact of ac contactor and burning of coil  
Repair or replace contactors
 
 
can not start 3.
The power switch is not closed, malfunction or damaged
 
 
Close the switch and replace it if the power indicator does not turn on
  4.
Thermal relay trip or damage
 
 
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started
  Water level is too low  
Put water in the sink
 
 
  The motor burned  
Repair or replace the motor
 
 
  1.Line is loose  
Check wiring and tighten connectors
 
 
  2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
The manual is normal 3The frequency converter is damaged Repair or replace
Automatic transmission failure 4.Pressure switch damage Repair or replace
  5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage
 
The pump consumes too much power
 
 
 
Too much flow, impeller wear
 
 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow
High Head Sewage Pump of Liquid
High Head Sewage Pump of Liquid

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.