T≤80ºC | Medium temperature≤100ºC |
Q=36~180m³/h | H=8.5~48.5m |
n=960/1440/2920 r/min | P=4~30KW |
Dna=70~150mm | DNm=50~150mm |
Symptoms |
Cause Analysis |
Method of exclusion |
Pump no water
|
1, water pipe leakage 2, suction stroke is too high 3, pipe resistance is too large or blocked |
1, to prevent leakage 2, lower the pump installation location 3, clean up the pipeline |
|
l, inlet diameter is too small 2, impeller flow blockage 3, head is too high 4, the speed is too low 5, pump reverse |
1, exchange the inlet pipe 2, cleaning the impeller 3, open a large outlet valve 4, restore the rated speed 5, change the wire connection |
Low head |
1, traffic is too large 2, the speed is too low 3, seal damage |
1, off the small outlet valve 2, restore the rated speed 3, replace the shaft seal |
Power is too high, the motor overheats |
l, traffic is too large 2, blocked the pump flow impeller 3, the machine axis coaxial tolerance is too large |
l, off the valve 2, eliminate the blockage 3, adjust the pump center |
Bearing overheating |
1, excessive or insufficient bearing cavity grease 2, pump shaft bending 3, the machine axis coaxial tolerance is too large |
1, check after the change 2, straighten or replace 3, adjust the pump center |