Multistage Vertical Fire System Water Pump Water Supply Application

Product Details
Customization: Available
Max.Head: >150m
Max.Capacity: >400 L/min
Still deciding? Get samples of US$ 137/Set
Request Sample

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
65
Year of Establishment
1998-09-10
  • Multistage Vertical Fire System Water Pump Water Supply Application
  • Multistage Vertical Fire System Water Pump Water Supply Application
Find Similar Products

Basic Info.

Model NO.
XBD-LV
Impeller Number
Multistage Pump
Working Pressure
High Pressure Pump
Influent Type of Impeller
Clear Water
Position of Pump Shaft
Vertical Pump
Impeller
Closed
Usage
Pump, Pumps, Condensate Pump, Slurry Pump, Circulating Pump
Type
Xbd-LV
Color
Red
Material
Cast Iron
Motor
100% Cooper Wire
Pressure
High Pressure
Theory
Centrifugal
Transport Package
Wooden Box
Specification
ISO9001/CE
Trademark
LYSON or OEM
Origin
Shanghai, China
HS Code
8413709990
Production Capacity
5000/Month

Product Description



Multistage Vertical Fire System Water Pump Water Supply Application



Products Name: XBD-LV Multistage Vertical Fire System Fire Pump Water Supply Function 

Conditions of use: Suitable for conveying the temperature under 60 celsius water and similar to that of liquid water, pump system working pressure of up to 18 bar.

The scope of performance parameter: This series a total of 6 species, 50kinds of specifications and its

performance parameters range:

1 flow Q= 5~40 L/S

2. Lift H= 35 ~ 181 m

3. Speed n=2900  r/mi8

4. Power P=3~ 132kW

5. Inlet Dna=50~150 mm

6. Outlet Dna=40~100mm
fault phenomenon failure cause elimination methods
The manual is normal
Automatic transmission failure
1.No power supply or one or two phase power supply is needed
Check all phases of power supply and restore power supply

 
Water level is too low
Put water in the sink

 
The motor burned
Repair or replace the motor

 
1.Line is loose
Check wiring and tighten connectors

 
2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
3The frequency converter is damaged Repair or replace
4.Pressure switch damage Repair or replace
5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage

The pump consumes too much power

 

Too much flow, impeller wear

 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow