• Sewage Grinder Pump with Non-Jamming Pollution Discharge
  • Sewage Grinder Pump with Non-Jamming Pollution Discharge
  • Sewage Grinder Pump with Non-Jamming Pollution Discharge

Sewage Grinder Pump with Non-Jamming Pollution Discharge

Method: Combined Treatment
Usage: Industrial, Home, Agriculture, Hospital
Flotation Machine Type: Air Flotation Machine
Centrifuge Technology Use: Sedimentation
Centrifuge Installation: Vertical
Main Features: Wq Non-Jamming Pollution Discharge Pump
Samples:
US$ 100/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
WQ
Transport Package
Wood Box
Specification
CE
Trademark
liansheng or OEM
Origin
Shanghai, China
HS Code
84101330
Production Capacity
50000/30days

Product Description


Sewage Grinder Pump with Non-Jamming Pollution Discharge
Products Name:Sewage grinder pump with Non-Jamming

1. Exploitation conditions the WQ series is suitable does not surpass in the transportation temperature 60 Celsius the belt pellet sewage, the contamination, may also use in the clear water and the belt corrosive medium.

2. Performance parameter scope this series altogether has 5 varieties, 441 kind of specification its.

performance parameter scope is:

1. Current capacity Q=6~2650m3/h;

2. Lifts H=5~36m;

3. Rotational speed n=980, 1450, 2900r/min;

4. Power P=0.55~315kw;

5. Induction port diameter Dna=25~500mm;

6. Spout diameter DNm=25~500mm.
fault phenomenon failure cause elimination methods
  1.No power supply or one or two phase power supply is needed
Check all phases of power supply and restore power supply

 
  2.Poor contact of ac contactor and burning of coil
Repair or replace contactors

 
can not start 3.
The power switch is not closed, malfunction or damaged

 
Close the switch and replace it if the power indicator does not turn on
  4.
Thermal relay trip or damage

 
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started
  Water level is too low
Put water in the sink

 
  The motor burned
Repair or replace the motor

 
  1.Line is loose
Check wiring and tighten connectors

 
  2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
The manual is normal 3The frequency converter is damaged Repair or replace
Automatic transmission failure 4.Pressure switch damage Repair or replace
  5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage

The pump consumes too much power

 

Too much flow, impeller wear

 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow
Sewage Grinder Pump with Non-Jamming Pollution Discharge
Sewage Grinder Pump with Non-Jamming Pollution Discharge

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
65
Year of Establishment
1998-09-10